Dilution Refrigerators with Superconducting Magnets

Dilution Refrigerators with Superconducting Magnets www.phwiki.com

Dilution Refrigerators with Superconducting Magnets

Rombouts, Christine, Contributor has reference to this Academic Journal, PHwiki organized this Journal Dilution Refrigerators with Superconducting Magnets Andrey Penzev, Project Engineer, Cryogenic Ltd Integration of Cryogen Free DR(Leiden Cryogenics) with Superconducting Magnet Option1: Cryogen Free Room Temperature Bore Magnet with Insertable DR DR in addition to superconducting magnet cooled by separate pulse tube coolers Modular system. Easy to interchange DR with other inserts Use with top-loading probe or bottom-loading DR Fields up to 16 T Suitable as long as use with our range of cryogen-free magnet systems Suitable as long as use with Leiden DR type CF200, CF450, CF650 or CF1000 Room Temperature magnet bore; 50 mm sample space in DR Integration of Cryogen Free DR(Leiden Cryogenics) with Superconducting Magnet Option2: Modular Cryogen Free System in Shared Vacuum Space Dilution Refrigerator (DR) in addition to high field magnet in shared cryostat Separate pulse-tube coolers as long as magnet in addition to DR Top loading Leiden DR as long as temperatures down to 10mK Large 3D cryogen free vector magnet (9 T / 5 T / 1 T) 4 Tesla rotating magnetic field vector Use with top-loading probe as long as easy sample change 50 mm 4K magnet bore, 30 mm sample space in DR

Mitchell Technical Institute SD www.phwiki.com

This Particular University is Related to this Particular Journal

Integration of Cryogen Free DR(Leiden Cryogenics) with Superconducting Magnet Option3: Cryogen-Free DR with Integrated Magnet Magnet thermally linked to the cryocooler 2nd stage Ideal as long as smaller magnets up to 17T or small vector magnets up to 7T/2T/2T Single pulse tube cryocooler as long as cooling both magnet in addition to DR Magnet operation at 4K Use with top-loading probe Fast Sample Change 64 mm magnet bore, 50 mm sample space in DR Integration of Cryogen Free DR(Leiden Cryogenics) with Superconducting Magnet Option4: Cryogen Free Magnet & Integrated Variable Temperature Sample Space With DR Insert Adapted MCK model DR inserted into 50 mm 1.6 K–300 K VTI VTI cooling power used as long as condensing stage of DR Versatile solution as the magnet system can also be used with other inserts in addition to measurement probes including He3, heated probes, rotator, VSM etc. Bottom loading DR with options of sample in liquid or sample in vacuum Suitable as long as use with systems up to 18 T in addition to neutron-scattering split-pair systems 50mm 4K magnet bore, 30mm sample space in DR Magnetic field compensation on the mixing chamber plate: St in addition to ard: down to 300 Gauss; Improved: down to 100 Gauss. Field up to 16T Compensated Magnets as long as CF Dilution Refrigerators

Top-Loading Sample Probe with Wire Connection at Mixing Chamber 72 dc wires, 8 coaxial cables Sample at T<10mK without field; at T<17mK at 14T => Fast sample exchange Dilution Refrigerator Insert with Sample Loading Tube UHV compatible sample loading tube ( as long as STM applications – UNISOKU Co., Ltd, Japan) Liquid helium cryostat with solenoid up to 16T or vector magnet 9T-2T-2T with 75mm bore; DR base temperature < 30mK; Sample access tube Ø16mm/Ø19mm; Sample space Ø66mm x 165mm long. Dilution Refrigerator Insert with Sample Loading Tube Automated Gas H in addition to ling System The gas h in addition to ling system is specifically designed as long as safe in addition to reliable h in addition to ling of 3He-4He mixture gas during operation of a dilution refrigerator. The system electronics is based on OMRON industrial automation components to provide fault-free operation. Touchscreen interface provides a manual mode as well as a set of automated sequences as long as helium mixture condensation, circulation in addition to recovery. Work in progress: DR Option as long as Cryogen Free Measurement System Cooling insert compatible with 25mm/30mm VTI: Field up to 18T; Base temperature goal: 50mK; achieved: 75mK as long as 25mm, 65mK as long as 30mm. Compatible with our universal 6-pin plug Sample change in addition to ultralow temperature measurements within 1 working day! Work in progress: DR Option as long as Cryogen Free Measurement System Leaders in integrated DR/magnet system technology Flexibility in meeting customers’ requirements Complete control of all aspects of design, technology in addition to production Extended customer support including on-line assistance with programming in addition to running experiments THANK YOU Rombouts, Christine Builder and Developer Contributor www.phwiki.com

Rombouts, Christine Contributor

Rombouts, Christine is from United States and they belong to Builder and Developer and they are from  Newport Beach, United States got related to this Particular Journal. and Rombouts, Christine deal with the subjects like Building/Construction; Home Building; Landscape Architecture

Journal Ratings by Mitchell Technical Institute

This Particular Journal got reviewed and rated by Mitchell Technical Institute and short form of this particular Institution is SD and gave this Journal an Excellent Rating.